Double Glazing Manufacturers

IGUMA (Insulated Glass Unit Manufacturers Alliance) is a group of Glass Processors who have agreed to an (independently verified) testing regime.  Your IGUMA Member supplier can provide you with a copy of the current compliance certificate for the product you are purchasing.

NZS4223.2:2016 requires IGU to be tested and demonstrate compliance.  IGUMA members who comply with IGUMA-BS EN1279 testing also comply with the requirements of Section 5 of NZS 4223.2:2016.  Paragraph 5.1.3 of the standard refers to the “Acceptable period between tests” and requires compliance testing to be conducted at least every two years.

Region Member Plant Address Auditor Licence No. Audit Valid ‘til
Auckland FMI Building Innovation Ltd 100 Carbine Rd, Mt Wellington BV 125 30 May 2026
Glass Team Ltd 11 Volger Dr, Wiri CSi 7292 15 April 2027
Metro Performance Glass 5 Lady Fisher Pl, Highbrook BV 103 23 March 2027
Viridian Glass 15 Waiouru Rd, Highbrook BV 122 19 July 2026
Waikato Architectural Glass Products 137 Swayne Rd, Cambridge BV 2904 04 Dec 2030
CM Glass Ltd 5 Norris Ave, Te Rapa, Hamilton BV 107 02 Aug 2026
Glasslines NZ Ltd 296 Peake Rd, Cambridge BV 127 28 Feb 2027
Christchurch FMI Building Innovation Ltd 53 Izone Dr, Rolleston BV 126 11 Dec 2026
Metro Performance Glass 700 Halswell Junction Rd, Hornby BV 116 10 Sept 2026
Stake Glass 3 Distribution Ln, Sockburn CSi 7130 08 Aug 2026
Viridian Glass 25 Pilkington Way, Wigram BV 118 13 Aug 2026

Identification of Insulating Glass Units

The New Zealand Building Code Clause B2 (amendment 9, January 2017) modifies NZS 4223 Part 2 as follows:

5.3 Marking

Insulating glass units shall be permanently and clearly marked. As a minimum, marking shall include the following:

a) The name or registered trademark of the manufacturer or supplier;

b) The date of manufacture (use the year as the minimum), and

c) Complies with NZS 4223.2:2016.

Marking shall be visible after the IGU has been installed, and must be legible and durable for the life of the unit.

NOTE:

  • Etching and permanent laser marking are acceptable means for marking insulating glass units.  Externally affixed adhesive labels are not acceptable.
  • Additional Marking may be used by the manufacturer.